From 60d3abc6ecdc21b4ab921d34a55b4af48690f55a Mon Sep 17 00:00:00 2001 From: Julien Dessaux Date: Thu, 11 Mar 2021 18:53:14 +0100 Subject: Rewrote the whole website to get rid on a heavy theme --- content/en/blog/miscellaneous/bacula-bareos.md | 38 -------------------------- 1 file changed, 38 deletions(-) delete mode 100644 content/en/blog/miscellaneous/bacula-bareos.md (limited to 'content/en/blog/miscellaneous/bacula-bareos.md') diff --git a/content/en/blog/miscellaneous/bacula-bareos.md b/content/en/blog/miscellaneous/bacula-bareos.md deleted file mode 100644 index a5fd0be..0000000 --- a/content/en/blog/miscellaneous/bacula-bareos.md +++ /dev/null @@ -1,38 +0,0 @@ ---- -title: "Some bacula/bareos commands" -linkTitle: "Some bacula/bareos commands" -date: 2018-01-10 -description: > - Some bacula/bareos commands ---- - -Bacula is a backup software, bareos is a fork of it. Here are some tips and solutions to specific problems. - -## Adjust an existing volume for pool configuration changes - -In bconsole, run the following commands and follow the prompts : -{{< highlight sh >}} -update pool from resource -update all volumes in pool -{{< /highlight >}} - -## Using bextract - -On the sd you need to have a valid device name with the path to your tape, then run : -{{< highlight sh >}} -bextract -V - -{{< /highlight >}} - -## Integer out of range sql error - -If you get an sql error `integer out of range` for an insert query in the catalog, check the id sequence for the table which had the error. For -example with the basefiles table : -{{< highlight sql >}} -select nextval('basefiles_baseid_seq'); -{{< /highlight >}} - -You can then fix it with : -{{< highlight sql >}} -alter table BaseFiles alter column baseid set data type bigint; -{{< /highlight >}} -- cgit v1.2.3